Duet Web Control and Repetier Server Macros
Baby Stepping - clear (set zero)
M290 R0 S0 ;clear babystepping
Baby Stepping - Down 0.1 mm
M290 S-0.1
Show network config
M552
M540
Change to static IP address (switch mode)
This macro makes only sense in Repetier Server!
For Duet of Trikarus we use 169.254.XXX.XXX. This also could be integrated/replaced in config.g file.
M552 S0 ;disable network
;M553 P255.255.0.0
M553 P255.255.255.0 ;set netmask
M552 S1 P169.254.XXX.XXX ;set static IP
Change to static IP address (mesh mode)
In mesh mode Duet receives a changing IP by DHCP all the time. But you can also set a static IP address if that IP is free and not conflicting with other devices. It can be a good idea to use IP addresses in range 10.149.0.2 - 10.149.0.254. For Duet of Trikarus we use 10.149.YYY.YYY. This also could be integrated/replaced in config.g file. Please note that hangdevice needs to be in the same network (e.g. 10.149.YYY.YYY), otherwise it is not reachable!
At the moment this mode is not used
;M552 S0 ;disable network
;M553 P255.255.0.0
;M553 P255.255.255.0 ;set netmask
;M552 S1 P10.149.YYY.YYY ;set static IP
M117 "Not used at the moment. Please use dynamic IP address"
Change to dynamic IP address (mesh mode)
M552 S0 ;disable network
M552 S1 P0.0.0.0
Allow outbound movements
M564 S0 H0
Disallow outbound movements
M564 S1 H0
Enable Smart Steppers
G0 H2 A0.01
G0 H2 B0.01
G0 H2 C0.01
G0 H2 D0.01
Diagnostics (M122)
M122
rotaryEncoderTest
;heat up the nozzle to 205 °C and wait for it
G10 P0 R140 S205
T0
M116
;50 times extrude and retract 5 mm with 60 mm/s
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
G1 E-5 F3600
G1 E+5 F3600
Turn off Laser Pointers
In Repetier Server this works not fine out of the box using the "fan control", so we use a special macro (not required for Duet Web Control).
Keine Kommentare vorhanden
Keine Kommentare vorhanden