Direkt zum Hauptinhalt

Ceiling module | Relay JQC-3FF-S-Z

grafik.png grafik.png grafik.png grafik.png grafik.png

This relay is used to switch on the Power Supply by Raspberry Pi GPIO.

Specifications

  • in line with international safety standards (control area and the load area has a separate slot)
  • double-sided FR-4 circuit board design
  • LED status
    • pull up bright (green light is on)
    • disconnect is not bright (green light is off)
    • red LED signalizing power
  • blue KF301 terminal
  • module size: 43x17x18.5mm
  • net weight: 15g
  • Module Interface Output Section
    • NO - Normally Open
    • COM - Common
    • NC - Normally Closed
  • Module Interface Input section
    • VCC: Connect 5V power supply positive (according to the relay voltage)
    • GND: Connect 5V power supply negative
    • IN: relay module signal trigger (low level active)
    • High and low meaning:
      • High-level trigger refers to the VCC side of the positive voltage and the trigger side of a trigger connection, when the trigger side has a positive voltage or to reach the trigger voltage, the relay is sucked.
      • Low-level trigger refers to the GND side of the negative voltage and the trigger side of a trigger connection, when the trigger side of the 0V voltage or voltage can be triggered when the relay is pulled.
  • Relay contact capacity: 250V 10A (AC) or 30V 30A (DC)
  • Electrical parameters

    5 V 4 mA 65 mA 0-2 V

    2 mA

    9 V 5 mA 45 mA 0-4 V 3 mA
    12 V 5.5 mA 42 mA 0-4 V 3 mA

    24 V  

    12 mA 40 mA 0-12 V 3 mA